Kistler Model 8752A Industrial K-Shear® Accelerometer
The 8752A50 and the 8752A50M5 high temperature 165°C version and industrial accelerometers that feature reliability and accuracy characteristics required for use in the most demanding of machine vibration measurements. With Kistler's unique K-Shear design, the inaccuracies long associated with industrial acceleration measurements are eliminated.
Highly accurate machinery housing vibration measurements are possible because the K-Shear is immune to base strain. Abrupt changes in surface temperature do not cause false alarms since K-Shear is insensitive to thermal transients. Because K-Shear is immune to transverse motion, the accelerometer is sensitive to acceleration only in the axis of interest. The quartz shear sensing element provide long-term stability required for dependable trend measurements. An integral Piezotron® impedance converter provides a low impedance voltage output, ensuring reliability. • Low impedance voltage mode • Quartz shear stability and precision • Accurate on flexible and stiff surfaces • Insensitive to thermal transients • High temperature version available • Case ground isolated • Conforming to CE Kistler Model 8752A Industrial K-Shear® Accelerometer |